 ASAP, LLC1511 Neave Street Covington, KY 41011 Phone: (859) 581-6990 Toll Free: (877) 987-2800 Fax: (859) 581-6821 info@asapanalytical.com |
 |
Select one of the following to jump down to that section:
 |
 |
 Capillary 0-100psi, S/SL Inlet for Agilent 6890  Inertium™ Technology, makes the TITAN Family the most inert GC inlets available  Multi Liner Options, Superior Performance  Upgradeable |
Part Numbers
| TITAN MODEL SL |
 |
Capillary 0-100psi, S/SL Inlet |
| 050 |
|
Splitless Performance Enhancement Wafer |
 |
 |
 Latest advancement in GC inlet technology  0-100psi, S/SL with PTV Large Volume capability  Inertium™ Technology, makes the TITAN Family the most inert GC inlets available  Multi Liner Options, Superior Performance  Upgradeable |
Part Numbers
| TITAN MODEL XL |
 |
Capillary 0-100psi, S/SL, PTV w/EPC and Cooling |
| 001 |
|
LN2 Cooling |
| 002 |
|
CO2 Cooling |
| 003 |
|
Air Cooling |
| 050 |
|
Splitless Performance Enhancement Wafer |
For increased sensitivity, the Titan™ large volume injectors have been packaged with IST for GC/MS software. This allows the Titan™ systems to utilize the power of IST for GC/MS to "see through" the matrix and identify the fingerprint/signature of the compounds of interest. Please Contact Us for more information about this tremendous offer.
Part Numbers
| MVI-1000 |
 |
MAGNUM SL Extended Length Transferline for GC.MSD.IRD |
| MVI-2000 |
|
MAGNUM XL Extended Length Transferline for GC.MSD.MSD |
Part Number
| ICT-1000 |
 |
Igloo Cryo Trap |
 |
 |
 Ferrules  Liners  O-Rings  Septa  Two Column Interfaces |
 |
 |
 Improved Design  Longer Service Life  90 Day Warranty  $1,795.00  Compatible with HP5921A and HP2350A |
Now you can bring your HP/Agilent Chemstation into the 21st Century with one of ASAP Analytical’s Computer Performance Solutions. Why should you continue to run your GC, LC or MSD Chemstation under an obsolete Windows Operating system? Now ASAP Analytical has the technology to increase your productivity and each solution is customized to meet your needs.
 Pre-loaded systems under XP Pro, 2000 Pro, NT4.0 and Windows 98.  Notebooks, desktops and tower systems configured to your specifications.  Network solutions available.  Choice of quality printers.  LCD TFT Flat Screen and CRT Monitors.  Latest Certified Chemstation upgrades.  GPIB and LAN communication.  USB supported devices.  Co-configured MSD and GC/LC Chemstations on one PC.
|
The 5973 MSD is the industry standard for Mass Spectrometry, but prior to 2001, these systems communicated using the slow, antiquated, General Purpose Interface Bus (GPIB). Until now, the only way to update your MSD system was expensive and time consuming.
You can now upgrade the communication of your 5973A to the latest LAN performance at an affordable price. ASAP’s Lan Enhancement Package provides additional speed, reliability and flexibility to your 5973A MSD. Standard upgrades are done on-site in one day.
 ASAP LAN Enhancement Bundles with MSD Chemstation Software upgrades available.  Add an ASAP Computer Performance Bundle for the latest and fastest processing and graphics available.  Improve electrical isolation by eliminating ground-loop paths from the GPIB shield – better thunderstorm durability.  More rapid tuning of your 5973 MSD.  More reliable communication with LAN.  Latest performance enhancements and firmware available on LAN-Enhanced systems.
|
The Sievers 355 Sulfur Chemiluminescence Detector (SCD) is the most sensitive and selective chromatographic sulfur detector available for the analysis of sulfur compounds. The SCD sulfur analyzer utilizes a Dual Plasma Burner to achieve high temperature combustion of sulfur containing compounds to form sulfur monoxide (SO). A photomultiplier tube detects the light produced by the chemiluminescent reaction of SO with ozone. This results in a linear and equimolar response to the sulfur compounds without interference from most sample matrices. Since measuring trace levels of sulfur compounds is of great importance to a number of industries, the SCD has become an important analytical tool for detecting sulfur, problem solving and monitoring product quality.
 |
 |
 Sulfur specific detection for Gas Chromatography (GC) or Supercritical Fluid Chromatography (SFC)  Picogram detection limits  No hydrocarbon quenching  Linear, equimolar response to sulfur compounds  ASTM Methods approval  Adapters for simultaneous SCD and FID operation |
The Sievers® 255 Nitrogen Chemiluminescence Detector (NCD) builds on GE Analytical Instruments expertise in chemiluminescence detection technology. The NCD is a nitrogen specific detector that produces a linear and equimolar response to nitrogen compounds. This is accomplished by using a stainless steel burner to achieve high temperature combustion of nitrogen containing compounds to form nitric oxide (NO). A photomultiplier tube detects the light produced by the subsequent chemiluminescent reaction of NO with ozone. Because of the specificity of the reaction, complex sample matrices can be analyzed with little or no interference.
 |
 |
 Nitrogen specific detection for Gas Chromatography (GC) or Supercritical Fluid Chromatography (SFC)  Picogram detection limits  No hydrocarbon quenching  Linear, equimolar response to organic nitrogen compounds  Responds to ammonia, hydrazine, hydrogen cyanide, and NOX  Adapters for simultaneous NCD and FID operation |
The Sievers Sulfur Chemiluminescence Detector (355 SCD) and Nitrogen Chemiluminescence Detector (255 NCD) are the world's most sensitive and selective chromatographic detectors for sulfur and nitrogen-containing compounds. With the development of the new Sievers Dual Plasma™ Burner and Controller for use with both detectors, the SCD and NCD now offer even better analytical performance, ease of use, lower maintenance, and faster start-up and equilibration times.
 |
 |
Dual Plasma Burner
 Heated base for enhanced baseline stability  Controlled base temperature for (by GC) to stabilize column output temperature  Drop-in burner mount for easy installation on major GC brands  Burner safety shroud to prevent accidental burns  Longer ceramic tube life Dual Plasma Controller
 Electronic flow sensors and convenient digital display for easy method development and monitoring hydrogen and oxidant and flow rates in real time  Narrow footprint (fits on top of SCD and NCD)  Embedded Nitrosamines option control for the NCD  Elimination of internal sulfur traps and the decoking valve  Universal power outlet
|
 |
 |
 1.6 - 800 amu in 0.1 steps  Lightweight, 70 lbs.  15"L x 23"W x 15"H  Completely portable MS based on Agilent Analyzer  Can be used in the field or in the lab.  Self-contained Hydrogen bottle for up to 160 hours use.  Connection to Standard Lab Cylinder (He or Hydrogen) provided. |
If you would be interested in a demo of the Portable GC.MSD system, ASAP has an experienced spectroscopist who can showcase the many features and benefits of this system in one afternoon. To schedule a demo please contact us.
This dedicated FTIR detector for an Agilent GC is the only analytical infrared instrument designed for the chromatographer’s point-of-view. The result is an instrument that requires a minimum bench space with optimized, dedicated optics for highest sensitivity. The IRD software is integrated into GC software and provides efficient instrument control and data acquisition.
 |
 |
 More positive compound identification - with multi-dimensional data from the most powerful instrument combination for organic compound analysis; obtain retention times, infrared spectra and mass spectra from a single injection  Identify more compounds - because infrared and mass spectral data are complementary  Increase productivity - hyphenated system can produce more and better data in less time  Get accurate, reproducible data - from linear, high stability instrumentation  Save bench space - entire GC/IR/MS system with PC controller takes only 158 cm of bench space |
 |
 |
 Elimination of post-extraction sample cleanup or purification results in drastic cuts in sample prep time and labor costs  Detection and quantification of priority pollutant organic compounds within a single, analytical technique enhances overall instrument productivity  Increased sensitivity  Substantial improvement in chromatographic run times - from 40 minutes to as little as 10 minutes per sample - dramatically increases sample throughput  Reduction of total sample testing time yields 3X to 5X reductions in labor costs and significant sample throughput gains  Unique ability to identify internal standards in surrogates in the presence of high levels of matrix interferences minimizes the need for sample dilution  Built-in Compound Library allows methods to be developed in minutes  Intuitive Windows graphical user interface means you're up and running quickly |
For increased sensitivity, the Titan™ large volume injectors have been packaged with IST for GC/MS software. This allows the Titan™ systems to utilize the power of IST for GC/MS to "see through" the matrix and identify the fingerprint/signature of the compounds of interest. Please Contact Us for more information about this tremendous offer.
IST for GC/MS is the most powerful data analysis software for mass spectrometry on the market today. Powered by Accurithm™, a unique set of signature detection algorithms, IST for GC/MS provides fast and accurate identification and quantification of organic compounds in complex mixtures in seconds!
|
 |